MEDICALIP LOGO

WHY DEEPCATCH X

One routine image. A broader view of health.

DeepCatch X quantifies cardiovascular risk, TB- and emphysema-suggestive findings, and 3D lung information from a single chest X-ray—adding broader health insight while keeping the established examination workflow.

DeepCatch X whole chest X-ray analysis
01

Keep existing equipment

No need to replace or add to the chest X-ray systems already in use.

02

Broader insight

Analyze cardiovascular, pulmonary, and lung-volume information together.

03

Quantitative results

Turn what was only assessed by eye into measurements and visualizations.

04

Beyond the exam

Support follow-up through prior-image comparison and risk stratification.

CARDIOVASCULAR SCREENING — DEEPCATCH X AORTA · HEART

See the heart and aorta together from a single X-ray

Configure Aorta and Heart as one cardiovascular screening pathway to quantify aortic diameter and heart-size information.

DeepCatch X Aorta

MFDS approvedFDA 510(k) submitted

Automated maximum thoracic aortic diameter measurement

Support screening for asymptomatic aortic dilation risk at the chest X-ray stage.

  • Measure and visualize maximum ascending and descending aortic diameters
  • Support follow-up imaging review for suspected dilation
  • External validation n=17,011
Aorta analysis example labeled normal
Normal
Aorta analysis example labeled needs attention
Needs attention

DeepCatch X Heart

MFDS approved

Automated heart size and CTR measurement

Quantify the heart and thorax to support review of cardiomegaly-suggestive cases.

  • Automated heart volume and area
  • Heart and thorax width with CTR
  • 96.8% cardiomegaly screening accuracy
Heart size and CTR analysis example labeled normal
Normal
Heart size and CTR analysis example labeled needs attention
Needs attention

PULMONARY DISEASE SCREENING — DEEPCATCH X TB · PULMO

From active TB detection to emphysema-suggestive regions

Present lesion location and extent through scores, heatmaps, and regional masks to support triage of cases that need review in high-volume screening.

DeepCatch X TB

MFDS approved

Active TB detection and monitoring

Detects active TB on chest X-rays and provides results as a score and heatmap.

  • Active TB detection with an abnormality score
  • Heatmap visualization of TB lesion location
  • Lesion change monitoring through comparison with prior X-rays
TB abnormality score and heatmap

DeepCatch X Pulmo

Visualize emphysema-suggestive regions

Support review of suspected regions through an AI mask overlay.

  • Emphysema-suggestive region mask
  • Low Attenuation Area analysis
  • Internal / external validation AUC 0.90 / 0.87
Emphysema-suggestive region analysis example

3D QUANTITATIVE ANALYSIS — DEEPCATCH X TORSO

Measure 3D lung volume from an X-ray without a pulmonary function test

Quantify lung volume across respiratory phases and provide tissue-separated outputs to support functional assessment and change review.

DeepCatch X Torso

MFDS approved

Tissue separation and quantification from one X-ray

Deliver 3D lung information and purpose-specific separated images from a 2D chest X-ray.

  • 3D lung volume at inspiration, 1-second forced expiration, and expiration
  • Lung Only and Bone Only outputs
  • Bone-suppressed output for lung-region review
3D lung volume phase 01INSPIRATION
3D lung volume phase 02FORCED EXPIRATION
3D lung volume phase 03EXPIRATION

The TB abnormality score supports screening and triage and is not a standalone diagnostic criterion for active TB. Clinical assessment and confirmatory testing are required.

COMMERCIAL ADOPTION

Institutions using DeepCatch X

  • MEDI CHECK
  • Kangbuk Samsung Hospital
  • Chung-Ang University Hospital
  • Hanshin Medipia
  • Kwangdong Hospital
  • Pusan National University Yangsan Hospital
  • Sejong Hospital
  • DK Medical Systems

FAQ

Frequently asked questions

Find answers to common questions when considering DeepCatch X for your institution.

Do we need to replace our existing chest X-ray equipment?

No. We review your current chest X-ray equipment and examination environment, then recommend a configuration that works with the existing setup.

Does DeepCatch X require an additional acquisition?

No additional acquisition is required when existing chest X-ray images meet the supported imaging conditions, allowing you to expand screening insights from the established workflow.

Can we adopt only the products we need?

Yes. Aorta and Heart, TB and Pulmo, and Torso can be configured individually or in combination based on your screening goals.

Can DeepCatch X integrate with our existing PACS or screening system?

We review your current systems and workflow before recommending an integration approach. The detailed scope is agreed during implementation consultation.

What does the implementation process involve?

We assess your examination environment and goals, agree on the product configuration, and proceed through system integration, operational validation, and user guidance.

Expand existing X-ray screening without new equipment or scans.

Talk with our team about a DeepCatch X configuration for your environment and operational goals.

Talk to our team